WARNING:
If repairs are to be made to a syrup system, disconnect syrup supply from the applicable syrup system, then relieve
the system pressure before proceeding. If repairs are to be made to the CO2 system, stop dispensing, shut off the
CO2 supply, then relieve the system pressure before proceeding. If repairs are to be made to the unit electrical
system, make sure electrical power is disconnected from the unit before proceeding.
IMPORTANT: Only qualified Personnel should service internal components or electrical wiring
Should your unit fail to operate properly, check that there is power to the unit and that the hopper contains ice. If the
unit does not dispense, check the following chart under the appropriate symptoms to aid in locating the defect.
Trouble
BLOWN FUSE OR CIRCUIT
BREAKER
AGITATOR DOES NOT TURN,
AUGER DOES NOT TURN.
ICE DISPENSES CONTINUOUSLY.
SLUSHY ICE. WATER IN HOPPER.
AGITATOR TURNS, AUGER DOES
NOT TURN.
AUGER TURNS, AGITATOR DOES
NOT.
BEVERAGES DONOT DISPENSE
©2001-2010, IMI Cornelius Inc.

TROUBLESHOOTING

Probable Cause
A.
Short circuit in electrical wiring.
B.
Inoperative 24 VAC transformer.
C. Inoperative agitator motor.
D.
Shorted motor.
A.
A.No electrical power.
B.
Bent depressor plate (does not actu-
ate switch).
C. Inoperative dispensing switch.
D.
Inoperative interlocks, lids not
closed.
E.
Inoperative timer board.
F.
Inoperative 24 VAC transformer.
A.
Stuck or bent depressor plate (does
not release switch).
B.
Inoperative dispensing switch.
C. Improper switch installation.
D.
Inoperative timer board.
A.
Blocked drain.
B.
Unit not sitting level.
C. Poor ice quality due to water quality
or ice maker problems.
D.
Improper use of flaked ice.
A.
Inoperative auger motor.
B.
Inoperative or improper setting of
speed control.
C. Inoperative rectifier.
D.
Ice jam.
E.
Inoperative timer board.
A.
Inoperative agitator motor.
B.
Inoperative motor capacitor.
C. Inoperative timer board.
A.
No 24 volts to dispensing valves.
B.
No CO
pressure.
2
- 17 -
PR150 BC Ice Drink Dispenser Operator's Manual
A.
Repair electrical wiring.
B.
Replace transformer.
C. Replace agitator motor.
D.
Replace Agitator Auger motor.
A.
Restore electrical power.
B.
Replace depressor plate.
C. Replace dispensing switch.
D.
Replace interlocks.
E.
Replace timer board.
F.
Replace transformer.
A.
Replace depressor plate.
B.
Replace dispensing switch.
C. Correct switch installation.
D.
Replace timer board.
A.
Unplug and flush out the drain.
B.
Level the unit.
C. Install water filter system. For ice
maker problems, consult ice maker
manual.
D.
Use correct ice.
A.
Replace auger motor.
B.
Replace speed control or re-adjust
speed control.
C. Replace rectifier.
D.
Clear ice jam.
E.
Replace timer board.
A.
Replace agitator motor.
B.
Replace motor capacitor.
C. Replace timer board.
A.
Make sure unit is connected to elec-
trical power. Check 24 VAC trans-
former.
B.
Check CO
tank pressure.
Publication Number: 620918702
Remedy
regulator. Check CO