5. Adjusting Syrup Flow Regulator - If water and syrup levels are uneven in the ratio cup, adjust by 
turning the dispensing valve syrup flow regulator adjusting screw labeled SYRUP as follows.
A.
For less syrup, turn the adjusting screw counterclockwise no more than 1/4 turn at a time.
B.
For more syrup, turn the adjusting screw clockwise no more than 1/4 turn at a time.
6. Repeat water-to-syrup ratio test and adjust syrup flow regulator as many times as necessary until proper ratio
of dispensed drink is achieved.
7. Remove syrup diversion tube assembly from dispensing valve.
8. Install dispensing valve front cover.