8. Open the front door of the cabinet below the hopper. This will give you access to the lower auger drive area
and the passage between the hopper and the auger for cleaning.
9. Using the previously prepared detergent solution, clean the valves, the hopper covers, agitator disk, agitator
assembly, interior of the hopper, both halves of the ice chute, auger, auger tubes, and the 
lower auger area of the auger housing. Thoroughly rinse all of the previously cleaned parts with potable water.
10. Reassemble the agitator assembly and disc into the hopper. Make certain the retaining screw is tight.
11. Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior of the hopper and the
agitator assembly. Go to the lower auger drive area and also spray with sanitizing solution. Allow to air dry.
12. Using the spray bottle, spray the inside of the two halves of the auger tube, the auger, the two halves of the
chute assembly, and the undersides of the right and left covers. Allow to air dry.
13. Reassemble the two halves of the auger tube and place back into it's mounting. Holding the auger by the
upper shaft end, insert into the guide tube. Make certain that the auger slips into it's drive pin. The chute
assembly will not assemble properly if the auger is not seated on it's drive pin. Reassemble the upper
auger and chute assembly onto the auger and lock down by snapping the ball onto the upper housing.
Reinstall the tower cover with the thumb screws.
14. Reinstall the covers. Put the right cover on first before you close the left cover.

Auger Housings

Last are the auger housings (Items 74 and 75). They are dislodged by pulling upward. Check their orientation and the
fact that the longer tube is on the front side. When positioning the housings back in the dispenser, the longer tube
should be placed first so as to seat in the lower housing to set up the orientation (top and bottom are marked on end
of the tube tab at the top), otherwise the ice chute spout will not point towards the front of the dispenser.
C
D
LEANING
ISPENSING
Refer to addendum supplied with the unit that is applicable to the manufacturer of the valves installed on the unit.

Sanitizing Syrup Tanks System

!
CAUTION:
Only trained and qualified persons should perform these cleaning and sanitizing procedures.
Sanitize syrup tanks system as follows:
1. Remove all the quick disconnects from all the tanks. Fill a suitable pail or bucket with soap solution.
2. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle
brush. (Do not use a wire brush). Rinse with clean water.
3. Prepare sanitizing solution and using a mechanical spray bottle, spray the disconnects. Allow to air dry.
4. Using a clean, empty tank, prepare five (5) gallons of the sanitizing solution. Rinse the tank disconnects
with approximately 9 oz. of the sanitizing solution. Close the tank.
5. Prepare to clean tank by filling clean five (5) gallon bucket with a mixture of mild detergent and potable water (120°F).
6. Connect a gas disconnect to the tank and then apply one of the product tubes to the cleaning tank. Oper-
ate the appropriate valve until liquid dispensed is free of any syrup.
7. Disconnect cleaning tank and hook up sanitizing tank to syrup line and CO
8. Energize beverage faucet until chlorine sanitizing solution is dispensed through the faucet. Flush at least
two (2) cups of liquid to ensure that the sanitizing solution has filled the entire length of the syrup tubing.
9. Allow sanitizer to remain in lines for fifteen (15) minutes.
10. Repeat step above, applying a different product tube each time until all tubes are filled with sanitizing solution.
11. For post-mix valves, remove the nozzle and syrup diffuser and clean them in a mild soap solution. Rinse
with clean water and reassemble the nozzle and syrup diffuser on the valve.