Chapter 10 Advanced Features
6
Click
to the right of "UPS Sync".
7
Click Edit.
8
Configure the desired settings, then click OK.
Notes:
• If the TeraStation is connected directly to a UPS, select "Sync with UPS connected to this TeraStation". If a
different Buffalo NAS device is connected to the UPS, select "Sync with UPS connected to another LinkStation or
TeraStation on the same network". After making this selection, enter the IP address of the Buffalo NAS device that
will be the sync source into "Other LinkStation or TeraStation's IP Address".
• When the TeraStation restarts after an automatic shutdown such as from a power outage or power supply issue,
verify that external power has been restored and a minute has passed since external power has been restored.
If the TeraStation is turned on while it is still running on the UPS and external power has been restored, the
automatic shutdown will not be performed, even after the specified time elapses.
• If the power supply from the UPS to the TeraStation stops and restarts when UPS recovery is enabled, the
TeraStation will automatically restarts.

Port Trunking

Two Ethernet cables can be used to establish two separate communication routes, providing LAN port redundancy
and improving communication reliability. The use of two Ethernet cables enables access to the TeraStation even if
one of the cables is disconnected.
The port trunking modes that can be set in the TeraStation are shown below:
Trunking Mode
Round-robin
*
Characteristics
Network packets are transmitted in sequential order from the first
available NIC slave through the last.
201