150
Repair > Milk Module Repairs (General)
11.12.6 Replace Micro Switches / Water Protection Clamp
Prerequisites
• Control board is removed → p. 148.
Procedure
1. Unplug the connector (circled in red) of the micro switches (2) on the control
board (3).
2. Pull away the water protection clamp (1) with the micro switches (2) from the
control board (3) by hand.
3. Lever the micro switches (2) out of the water protection clamp (1) by hand or with
the help of a small flathead screwdriver (see detail).
Momento 120 Service Manual
1
2
3
Version 1.4 EN
Fig. 116