11.12.9 Replace Water Coupling

Prerequisites
• (MCS) Hydraulic unit and PCB assembly are detached → p. 182.
• (PCS) Hydraulic unit and PCB assembly are detached → p. 160.
Procedure
1. Remove the FEP tube (A) from the water coupling (1).
2. Remove the silicone tube (B) including the hose fitting from the
water coupling (1).
3. Remove the water coupling (1) from the hydraulic unit.
Version 1.4 EN
Repair > Milk Module Repairs (General)
A
B
Momento 120 Service Manual
1
Fig. 122 
1
Fig. 123 
Removing FEP
tubes: → p. 142