10 M I L K M O D U L E - F U N C T I O N A L
D E TA I L S

10.1 Refrigerator and its Controllers

10.1.1 Overview

3
1) Ventilator 24 V DC 5.04 W with RPM
detection
• The compressor motor is equipped with a thermal fuse which is self resettable.
• The fan is equipped with a data signal to watch its state.
• If the refrigerator has been stored in a not upright position, it needs to be settled
down in upright position for 12 hours.
Version 1.4 EN

Milk Module - Functional Details

2) Compressor 208 - 240 V AC 50/60 Hz
3) Electronics
Momento 120 Service Manual
1
2
Fig. 29 