Removing FEP
tubes: → p. 142
146
Repair > Milk Module Repairs (General)
11.12.4 Replace Fridge Fan
2
1
take special care to not push or bend any of the copper pipes around the
compressor of the fridge!
Procedure
1. Unplug the electrical connector of the fan (2) from the hydraulic unit.
2. Pull out one tube on the outlet valve (4) and one tube from the RF-Box (3), see
details.
3. Pull the tubes out of their guides.
4. Loosen 2 screws (crosshead) on the fan cover (1).
Momento 120 Service Manual
3
4
Fig. 111