154
Repair > Milk Module Repairs (General)
4. Loosen 4 screws (TX9) on the metal holding plate (4).
5. Remove the metal holding plate (4) together with the plunger guide (5).
6. Remove the plunger (6) and the gasket (7) from the plunger guide (5).
Assembly tips
• Always replace the gasket (7)!
• Avoid cutting a new thread with the screws when remounting the metal holding
plate.
• Alternate between the screws on the metal holding plate (4) when turning them
in again to ensure that the holding plate is mounted flush on the valve (1).
Momento 120 Service Manual
6
7
1
4
5
5
Fig. 120 
Fig. 121 
Version 1.4 EN