6. Loosen one screw (TX20) on the cross beam (1) and on the chassis BU (4).
7. Do the same on the other side of the coffee module.
8. Remove the head base plate (3) including the cross beams (1) by pulling it away
on the coffee module handle (2).
Assembly tips
• Make sure that the cross beam (1) screws are countered with a square nut.
• Always replace the O-ring seated between the valve and hose adapters.
Version 1.4 EN
1
2
Repair > Coffee Module Repairs
3
4
Momento 120 Service Manual
Be cautious not
to lose the square
nuts countering the
screws on the cross
beam.
Fig. 71 