The milk foam
settings are part of
the maintenance menu
→ p. 34
28
Installation > Milk Foam Adjustment
4.7 Milk Foam Adjustment
4.7.1 MMI Menu for Foam Settings
1. Enter the maintenance menu via the machine settings → p. 33.
maintenance menu
clean the milk machine
adjust foam parameters
2. Tap on "adjust foam parameters".
cold foam se ings
33 %
air valve opening
4. The only parameter that is adjusta-
ble regarding the product quality is
the air valve opening for froth.
Changes of the air valve opening have the following impact on the product:
Air flow increases → foam becomes more solid.
If the air limit is exceeded → blow out, many big bubbles!
Air flow decreases → foam becomes more liquid.
Refer to the next 2 pages for optimal adjustment of both hot and cold foam.
Momento 120 Service Manual
adjust foam parameters
hot foam se ings
cold foam se ings
3. Select the hot/cold foam settings
depending on which you want to
adjust.
test
33 %
air valve opening
stop
5. With "test", a test product with this
settings is dispensed.
cold foam se ings
test
stop
Version 1.4 EN