Replace Emptying Valve - Nespresso Momento 120 Service Manual

Coffee/milk machine
Hide thumbs Also See for Momento 120:
Table of Contents

Advertisement

11.14.6 Replace Emptying Valve

1
2
This component and connected pipes are partially under pressure
(→ p. 15), follow the instructions on page 140 in advance!
Prerequisites
• Hydraulic unit and PCB assembly are detached → p. 182.
Procedure
1. Unplug the two electrical connectors (a+b) from the emptying valve (2).
2. Remove the emptying valve (2) from the boiler (1) in the same way as FEP tubes.
3. Remove the FEP tube (A) from the emptying valve (2).
4. Remove the emptying valve (2)
Version 1.4 EN
Repair > Milk Module Repairs (Metal Component Support)
A
Momento 120 Service Manual
Removing FEP
tubes: → p. 142
Fig. 160 
189

Hide quick links: