The illustration
shown is with the
pump removed – for
better visibility.
130
Repair > Coffee Module Repairs

11.11.10 Replace Main PCB

1,(2)
Prerequisites
• Main PCB cover is removed → p. 109.
Procedure
1. Unplug all connectors and receptacles from the main PCB (2).
2. Pull on the main PCB housing (1) until you hear it click.
3. Lift the main PCB (2) and housing (1) out of its slots (circled in red).