Media Temperatures; Air Humidity; Degree Of Protection And Safety Requirements; Installation Height - ProMinent Sigma2 S2Cb Operating Instructions Manual

Diaphragm motor-driven metering pump
Table of Contents

Advertisement

16.5.2

Media temperatures

PVT liquid end
SST liquid end
16.5.3

Air humidity

Air humidity
16.5.4

Degree of Protection and Safety Requirements

Degree of protection
Safety Requirements
16.6

Installation height

Data
Max. temperature long-term at max. oper‐
ating pressure
Max. temperature for 15 min at max. 2 bar
Minimum temperature
Data
Max. temperature long-term at max. oper‐
ating pressure
Max. temperature for 15 min at max. 2 bar
Minimum temperature
Data
Maximum air humidity*:
*non-condensing
Protection against contact and humidity:
IP 65 in accordance with IEC 529, EN 60529, DIN VDE 0470 Part 1
A CAN plug or the supplied sealing cap must always be
plugged into the CAN port for the HMI.
Degree of protection:
1 - mains power connection with protective earth conductor
Data
Maximum installation height*:
* with standard pumps: Fit at higher installation heights at your own risk.
with ATEX pumps: We urgently advise that you contact a specialist for
ATEX motors at higher installation heights!
Technical data
Value Unit
65 °C
100 °C
-10 °C
Value Unit
90 °C
120 °C
-10 °C
Value Unit
95 % relative
humidity
Value Unit
1000 m above
standard
zero
89