Sound pressure level

2.1 Safety information for ATEX designs

Intended use
Qualification of personnel
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, create a Declaration of Conformity, fit a company name‐
plate, ... .
4.
Complete the pump documentation / operating instructions.
Sound pressure level LpA < 75 dB in accordance with EN ISO
20361:2010-10
at maximum stroke length, maximum stroke rate, maximum back pressure
(water)
This chapter lists all safety information for ATEX designs. Safety informa‐
tion is listed again at the relevant points in these operating instructions.
This safety information is supplementary to or replaces the safety informa‐
tion for non-ATEX designs. If the safety information for ATEX designs con‐
tradicts the other safety information, then the safety information in this
chapter applies to ATEX designs.
Only operate an ATEX design pump in premises at risk from explosion
n
in accordance with the applicable guidelines.
The pump is not intended for metering flammable fluids in areas at
n
risk from explosion.
Do not expose the ATEX design to any sources of ionising radiation or
n
electromagnetic high frequency radiation in the range 10
or laser or ultrasound or lightning without putting in place measures in
line with EN 80079-38.
Do not use the ATEX design to meter media, which have a tendency
n
to produce an exothermic reaction or self-ignite without measures in
accordance with EN 80079-38.
Task
Planning the hydraulic installation
Electrical installation
Start up
Maintenance, repair
Troubleshooting
Explanation of the table:
Recognised competent person
To carry out explosion hazard inspections the competent person must
have:
Safety chapter
... 3x10
4
Qualification
ATEX qualified person, ATEX elec‐
trical technician
ATEX electrical technician
Skilled ATEX technician;
Checking the electrical installation:
Recognised competent person
ATEX qualified person, ATEX elec‐
trical technician
Qualified ATEX technician or ATEX
electrical technician - depending on
the fault;
Checking the electrical installation: