Safety Information For Atex Designs - ProMinent Makro TZ Operating Instructions Manual

Diaphragm metering pump
Table of Contents

Advertisement

Safety chapter
Install the motor - with designs without
motor
Sound pressure level

2.1 Safety information for ATEX designs

Intended use
Qualification of personnel
14
1.
Select a suitable motor - it must correspond to the data for
one of the motors from the "Motor data" table - see Chapter
"Technical data"
2.
Fit the motor correctly on the flange (qualified personnel).
3.
As you have converted an "incomplete machine" into a com‐
plete machine, you must perform a conformity assessment,
risk assessment, create a Declaration of Conformity, fit a
company nameplate, ... .
4.
Complete the pump documentation / operating instructions.
Sound pressure level LpA < 75 dB in accordance with EN ISO
20361:2010-10
at maximum stroke length, maximum stroke rate, maximum back
pressure (water)
This chapter lists all safety information for ATEX designs. Safety
information is listed again at the relevant points in these operating
instructions.
This safety information is supplementary to or replaces the safety
information for non-ATEX designs. If the safety information for
ATEX designs contradicts the other safety information, then the
safety information in this chapter applies to ATEX designs.
Only operate an ATEX design pump in premises at risk from
n
explosion in accordance with the applicable guidelines.
The pump is not intended for metering flammable fluids in
n
areas at risk from explosion.
Do not expose the ATEX design to any sources of ionising
n
radiation or electromagnetic high frequency radiation in the
range 10
4
... 3x10
15
Hz or laser or ultrasound or lightning
without putting in place measures in line with EN 80079-38.
Do not use the ATEX design to meter media, which have a ten‐
n
dency to produce an exothermic reaction or self-ignite without
measures in accordance with EN 80079-38.
Task
Planning the hydraulic installa‐
tion
Electrical installation
Start up
Qualification
ATEX qualified person, ATEX
electrical technician
ATEX electrical technician
Skilled ATEX technician;
Checking the electrical installa‐
tion: Recognised competent
person

Advertisement

Table of Contents
loading

This manual is also suitable for:

Makro tzmb

Table of Contents