2.6.7 Installing an internal fan control panel*
Push the control panel cable (Fig� 15-2) for the fan
through the recess (Fig� 15-1) in the support and clip
it into the designated cable guide�
Fig� 15
2.6.8 Screwing down the installation box on the
mounting frame
Secure the installation box in the installation cut-out
with 6 screws (3 x 12 mm), each angled towards the
outside� If this is not possible, the installation box
can be secured at the side to the front of the installa-
tion cut-out with 4 screws (3 x 12 mm)�
3x
2x
3x
Fig� 16
2.6.9 Screwing down the support on the
mounting frame
S 3004: Secure the support to the mounting frame
with 3 screws (3�5 x 16 mm) (Fig� 17)�
3x
Fig� 17
30090-00314 · 01 · 07/2022
1
2
3x
2x
3x
2x
2x
S 5004: Secure the support to the mounting frame
with 4 screws (3�5 x 16 mm) (Fig� 18)�
4x
Fig� 18
2.6.10 Installing the cover
CAUTION
Danger of cut injuries
Possible risk of cut injuries from sharp edges on
the cover�
Wear safety gloves�
S 3004: Fit the cover (Fig� 19-1) to the 2 centring
aids (Fig� 19-3) on the support (Fig� 19-2) angled
from above� Swivel in below until the cover engages
all round the support�
3
1
Fig� 19
S 5004: Fit the cover (Fig� 20-1) from the front on
the support (Fig� 20-1)� Press the cover onto the sup-
port until the cover engages all round� If necessary,
press the metal tabs down slightly on the centring
aid (Fig� 20-3) to ensure a fully resting position�
3
1
Fig� 20
Installation
2
2
EN