    – Modifications to the device (including accessories) – Modifications to the exhaust duct and the cowl – Failure to use original Truma parts as replacement parts and accessories – Failure to follow the installation and operating instructions.
  • Page 3: Important Operating Notes

    This heater was designed for installation in caravans and other trailers. The S 3004 / S 3004 P heater is also suitable for instal- If a canopy is fitted to the caravan, it is essential to lead the lation in motor homes.
  • Page 4: Operating Instructions

    Truma warm air system running. The S 3004 P heater (with piezo ignitor) is designed so that an auto ignitor (part no. 30580-01) can be retrofitted.
  • Page 5: Operation Of The Fan

    20 seconds. It is advisable to remove accumulated dust from the heat ex- changer, the floor plate and the fan wheel of the Truma warm air system at least once a year before the beginning of the heating season. Carefully clean the fan wheel with a paint- brush or small brush.
  • Page 6: Removing The Cover

    Removing the cover Auto ignitor battery change Do not remove the cover unless the heater is switched If no ignition spark is heard during start-up or only at intervals off and has cooled down. of more than one second, the battery must be replaced. The cover is unlocked by pushing the two locking levers (1) Always ensure that the heater is switched off before replac- outwards simultaneously.
  • Page 7: Technical Data

    S 3004 / S 3004 P: 3500 W S 5004: 6000 W Gas consumption S 3004 / S 3004 P: 30 – 280 g/h S 5004: 60 – 480 g/h Additional information according to EN 624 S 3004 / S 3004 P: Q = 4.0 kW (Hs);...
  • Page 8: Manufacturer's Warranty (European Union)

    The warranty must be claimed with an authorised service part- ner or at the Truma Service Centre. All the relevant addresses This Warranty is applicable in EU member states as well as in and phone numbers can be found at www.truma.com, in the Iceland, Norway, Switzerland and Turkey.
  • Page 9 Bei Störungen wenden Sie sich bitte an das Truma Las instrucciones de uso y montaje en su idioma Servicezentrum oder an einen unserer autorisierten pueden ser solicitadas al fabricante Truma o al Servicepartner (siehe www.truma.com). servicio Truma de su país.