Operation Method Of Synchronous Control; Synchronous Control Execution Procedure - Mitsubishi Electric iQ-F Series User Manual

Motion module
Table of Contents

Advertisement

1.3

Operation Method of Synchronous Control

Synchronous control execution procedure

The synchronous control is executed using the following procedure.
Preparation
STEP 1
STEP 2
STEP 3
Start
STEP 4
synchronous
control
Monitor the
STEP 5
synchronous
control change
Complete
STEP 6
synchronous
control
*1 Page 25 INPUT AXIS MODULE
*2 Page 72 CAM FUNCTION
*3 Page 87 SYNCHRONOUS CONTROL, Page 137 Synchronous Control Initial Position Parameters
*4 Page 166 Sample Program of Synchronous Control
1 OUTLINE OF SYNCHRONOUS CONTROL
20
1.3 Operation Method of Synchronous Control
Set the following parameters.
• Common parameters ([Pr.24], [Pr.82], [Pr.89],
[Pr.96], [Pr.97], [Pr.150], [Pr.151])
• Positioning parameters ([Pr.1] to [Pr.4],
[Pr.7] to [Pr.22], [Pr.25] to [Pr.42], [Pr.81],
[Pr.83], [Pr.84], [Pr.90], [Pr.95],
[Pr.116] to [Pr.119], [Pr.127])
• Extended parameters ([Pr.91] to [Pr.94])
Set "input axis parameters" for synchronous control.
*1
([Pr.300] to [Pr.304], [Pr.320] to [Pr.329])
*2
Set the cam data.
*3
Set "synchronous parameters" for synchronous
control. ([Pr.400] to [Pr.468])
Create a program that executes to start / change
control / stop synchronous control.
(Set "[Cd.380]Synchronous control start", start and
*4
stop the input axis operation and change the
reduction ratio)
Write the program, which is created
in STEP1 and STEP2, to the CPU module.
Turn ON the synchronous control start bit for
the axis that starts synchronous control.
Verify that it is during synchronous control.
Operate the input axis.
Monitor the synchronous control operation status.
Execute the control change for the speed change
ratio, cam No., etc.
Stop the input axis.
Verify the input axis is stopped and turn OFF the
synchronous control start bit for the axis that stops
synchronous control.
End of control
One of the following two methods can be used.
<Method 1>
Directly set (write) the parameters
in the Simple Motion module using
the engineering tool.
<Method 2>
Set (write) the parameters from
the CPU module to the Simple
Motion module using the program.
Turn ON the target axis bit in
"[Cd.380] Synchronous control start"
and start synchronous control
by the program in STEP 2.
Verify that it is during synchronous control in
"[Md.26] Axis operation status".
Operate the input axis by the program in STEP 2.
Monitor using the engineering tool.
Changing the control by the program in STEP 2.
Stop the input axis by the program in STEP 2.
Turn OFF the target axis bit in
"[Cd.380] Synchronous control start"
to stop synchronous control
by the program in STEP 2.