Mitsubishi Electric iQ-F Series User Manual page 162

Motion module
Table of Contents

Advertisement

■Synchronous parameters: Speed change gear
n: Axis No. - 1
Item
[Pr.434]
Speed change gear
[Pr.435]
Speed change gear smoothing time constant
[Pr.436]
Speed change ratio: Numerator
[Pr.437]
Speed change ratio: Denominator
■Synchronous parameters: Output axis
n: Axis No. - 1
Item
[Pr.438]
Cam axis cycle unit setting
[Pr.439]
Cam axis length per cycle
[Pr.440]
Cam No.
[Pr.441]
Cam stroke amount
[Pr.444]
Cam axis phase compensation advance time
[Pr.445]
Cam axis phase compensation time constant
[Pr.446]
Synchronous control deceleration time
[Pr.447]
Output axis smoothing time constant
■Synchronous parameters: Synchronous control initial position
n: Axis No. - 1
Item
[Pr.460]
Setting method of current value per cycle after main shaft gear
[Pr.461]
Setting method of current value per cycle after auxiliary shaft gear
[Pr.462]
Cam axis position restoration object
[Pr.463]
Setting method of cam reference position
[Pr.464]
Setting method of cam axis current value per cycle
[Pr.465]
Current value per cycle after main shaft gear (Initial setting)
[Pr.466]
Current value per cycle after auxiliary shaft gear (Initial setting)
[Pr.467]
Cam reference position (Initial setting)
[Pr.468]
Cam axis current value per cycle (Initial setting)
APPENDICES
160
Appendix 1 List of Buffer Memory Addresses (for Synchronous Control)
Buffer memory address
36460+200n
36461+200n
36462+200n
36463+200n
36464+200n
36465+200n
Buffer memory address
36470+200n
36472+200n
36473+200n
36474+200n
36476+200n
36477+200n
36482+200n
36483+200n
36484+200n
36485+200n
36486+200n
Buffer memory address
36500+200n
36501+200n
36502+200n
36503+200n
36504+200n
36506+200n
36507+200n
36508+200n
36509+200n
36510+200n
36511+200n
36512+200n
36513+200n

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq-f fx5Fx5-40ssc-sFx5-80ssc-s

Table of Contents