CONNECTION OF THE CONTROL

4.3.5 Assembly of the wires to PUSH IN terminals

ATTENTION
single-wire or fine-wire
Table 17:
Front view
Figure 19:
All manuals and user guides at all-guides.com
Malfunctions caused by loose cable connections!
► Observe metal sleeve length and stripping length
Cross-section
0.50 mm
2
with plastic collars
0.75 mm
2
1.00 mm
2
without plastic collars
1.50 mm
2
0.2...1.5 mm
2
Wire-end ferrules and stripping length
a)
b)
Assembly of the control cable
Press pusher by hand. Insert connecting wires into the respective hole, that no
single wires can be seen from the outside or bend outward. A first resistance must
be overcome when inserting. Release the pusher.
Check that the connecting wire is fixed and can not be pulled-out. It is important to
ensure that the connecting wire and not the insulation is clamped. The connecting
wire can also be inserted without pressing the pusher in case of cross-sections
upto 1.00 mm².
Metal sleeve
Wire-end ferrule
(DIN
46228-4)
(DIN
46228-1)
without wire-end
ferrule
a) Pusher
b) Wire hole
18
Stripping
length
length
10 mm
12 mm
12 mm
14 mm
12 mm
15 mm
10 mm
10 mm
10...15 mm
49