Installation And Connection; Construction Of The Unit; Figure 6: Construction Of The Unit; Figure 7: Connections Of The Front Side - KEB COMBIVERT H6 Instructions For Use Manual

Installation rectifier module
Hide thumbs Also See for COMBIVERT H6:
Table of Contents

Advertisement

INSTALLATION AND CONNECTION

4 Installation and Connection

4.1 Construction of the unit

Front view
Figure 6:
Construction of the unit
DANGER
Description
Terminal
+24V bus
0 V
DC bus+
DC bus-
Line terminal strip
Figure 7:
Connections of the front side
38
All manuals and user guides at all-guides.com
Remove the front cover
• Pull with both hands at the
lower end of the cover.
• Tilt cover forward to approx. 45
degrees, until the plates solve
above from the mounting.
• Remove the cover forward.
Remove the cover of the DC bus
• Compress lug of the cover,
remove forward.
Dangerous voltage
► Secure voltage disconnection of the DC bus at the power supply
and regenerative unit!
Connections of the front side
X1C.1
X1C.2
X1D.1
X1D.2
X1A
Front without cover
Termi-
Description
nal
X1C.3
+24V bus
X1C.4
0 V
X1D.3
DC bus (displayed with
protection against con-
tact for exterior units)
X1D.4
Snap-in for front cover
DC connection and brak-
X1B
ing resistor

Advertisement

Table of Contents
loading

Table of Contents