YASKAWA FP605 Installation & Primary Operation page 71

Ac drive for industrial fan and pump applications
Hide thumbs Also See for FP605:
Table of Contents

Advertisement

No.
(Hex.)
b1-03
Stopping Method Selection
(0182)
b1-04
Reverse Operation Selection
(0183)
C1-01
Acceleration Time 1
(0200)
RUN
C1-02
Deceleration Time 1
(0201)
RUN
C2-01
S-Curve Time @ Start of Accel
(020B)
C2-02
S-Curve Time @ End of Accel
(020C)
C2-03
S-Curve Time @ Start of Decel
(020D)
C2-04
S-Curve Time @ End of Decel
(020E)
C6-02
Carrier Frequency Selection
(0224)
d1-01 to d1-16
Reference 1 to 16
(0280 - 0291)
RUN
d1-17
Jog Reference
(0292)
RUN
d2-01
Frequency Reference Upper Limit
(0289)
d2-02
Frequency Reference Lower Limit
(028A)
E1-01
Input AC Supply Voltage
(0300)
E1-04
Maximum Output Frequency
(0303)
E1-05
Maximum Output Voltage
(0304)
E1-06
Base Frequency
(0305)
E1-09
Minimum Output Frequency
(0308)
YASKAWA TOEPC7106171FD FP605 DRIVE INSTALLATION & PRIMARY OPERATION
Name
V/f
OLV/PM
OLV/PM EZOLV
Sets the method to stop the motor after removing a Run command or entering a Stop command.
0 : Ramp to Stop
1 : Coast to Stop
2 : DC Injection Braking to Stop
3 : Coast to Stop with Timer
V/f
OLV/PM
OLV/PM EZOLV
Sets the reverse operation function. Disable reverse operation in fan or pump applications where reverse rotation is
dangerous.
0 : Reverse Enabled
1 : Reverse Disabled
V/f
OLV/PM
OLV/PM EZOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
OLV/PM
OLV/PM EZOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
OLV/PM
OLV/PM EZOLV
Sets the S-curve acceleration time at start.
V/f
OLV/PM
OLV/PM EZOLV
Sets the S-curve acceleration time at completion.
V/f
OLV/PM
OLV/PM EZOLV
Sets the S-curve deceleration time at start.
V/f
OLV/PM
OLV/PM EZOLV
Sets the S-curve deceleration time at completion.
V/f
OLV/PM
OLV/PM EZOLV
Sets the carrier frequency for the transistors in the drive.
1 : 2.0 kHz
2 : 5.0 kHz
3 : 8.0 kHz
4 : 10.0 kHz
5 : 12.5 kHz
7 : Swing PWM1 (Audible Sound 1)
8 : Swing PWM2 (Audible Sound 2)
9 : Swing PWM3 (Audible Sound 3)
A : Swing PWM4 (Audible Sound 4)
B : Leakage Current Rejection PWM
F : User Defined (C6-03 to C6-05)
V/f
OLV/PM EZOLV
OLV/PM
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV/PM
OLV/PM EZOLV
Sets the Jog frequency reference in the units from o1-03 [Frequency Display Unit Selection]. Set H1-xx = 6 [MFDI
Function Selection = Jog Reference Selection] to use the Jog frequency reference.
V/f
OLV/PM EZOLV
OLV/PM
Sets maximum limit for all frequency references. The maximum output frequency is 100%.
V/f
OLV/PM EZOLV
OLV/PM
Sets minimum limit for all frequency references. The maximum output frequency is 100%.
V/f
OLV/PM EZOLV
OLV/PM
Sets the drive input voltage.
V/f
OLV/PM
OLV/PM EZOLV
Sets the maximum output frequency for the V/f pattern.
V/f
OLV/PM EZOLV
OLV/PM
Sets the maximum output voltage for the V/f pattern.
V/f
OLV/PM EZOLV
OLV/PM
Sets the base frequency for the V/f pattern.
V/f
OLV/PM
OLV/PM EZOLV
Sets the minimum output frequency for the V/f pattern.
11 Drive Control and Programming
Description
71

Advertisement

Table of Contents
loading