YASKAWA FP605 Installation & Primary Operation page 36

Ac drive for industrial fan and pump applications
Hide thumbs Also See for FP605:
Table of Contents

Advertisement

7 Electrical Installation
Model
Terminal
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4034
-, +1
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4040
-, +1
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4052
-, +1
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4065
-, +1
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4077
-, +1
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4096
-, +1
36
Applicable Gauge
Recommended
Gauge
AWG, kcmil
AWG, kcmil
(mm
2
)
*1
14 - 8
8
(2.5 - 10)
14 - 8
8
(2.5 - 10)
14 - 8
8
(2.5 - 10)
14 - 8
10
(2.5 - 10)
14 - 4
8
(2.5 - 25)
14 - 4
8
(2.5 - 25)
14 - 4
6
(2.5 - 25)
14 - 4
8
(2.5 - 25)
14 - 4
6
(2.5 - 25)
14 - 4
6
(2.5 - 25)
14 - 4
4
(2.5 - 25)
14 - 4
8
(2.5 - 25)
14 - 4
4
(2.5 - 25)
14 - 4
4
(2.5 - 25)
14 - 4
4
(2.5 - 25)
14 - 4
6
(2.5 - 25)
8 - 2/0
4
(10 - 70)
8 - 2/0
3 or 2
(10 - 70)
8 - 2/0
2
(10 - 70)
8 - 2/0
6
(10 - 70)
8 - 2/0
2
(10 - 70)
8 - 2/0
1
(10 - 70)
8 - 2/0
1
(10 - 70)
8 - 2/0
6
(10 - 70)
IP20 Applicable Gauge
*2
AWG, kcmil
(mm
2
)
*1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
YASKAWA TOEPC7106171FD FP605 DRIVE INSTALLATION & PRIMARY OPERATION
Wire Stripping
Terminal Screw
Length
*3
Size and Shape
mm
10
M4
10
M4
10
M4
-
M5
18
M5
18
M5
18
M5
-
M6
18
M5
18
M5
18
M5
-
M6
18
M5
18
M5
18
M5
-
M6
-
M8
-
M8
-
M8
-
M8
-
M8
-
M8
-
M8
-
M8
Tightening Torque
N∙m (lbf∙in)
1.5 - 1.7
(13.5 - 15)
1.5 - 1.7
(13.5 - 15)
1.5 - 1.7
(13.5 - 15)
2.0 - 2.5
(17.7 - 22.1)
4.1 - 4.5
(36 - 40)
4.1 - 4.5
(36 - 40)
4.1 - 4.5
(36 - 40)
4.0 - 5.0
(35.4 - 44.3)
4.1 - 4.5
(36 - 40)
4.1 - 4.5
(36 - 40)
4.1 - 4.5
(36 - 40)
4.0 - 5.0
(35.4 - 44.3)
4.1 - 4.5
(36 - 40)
4.1 - 4.5
(36 - 40)
4.1 - 4.5
(36 - 40)
4.0 - 5.0
(35.4 - 44.3)
5.4 - 6.0
(47.8 - 53.1)
5.4 - 6.0
(47.8 - 53.1)
5.4 - 6.0
(47.8 - 53.1)
9.0 - 11
(79.7 - 97.4)
5.4 - 6.0
(47.8 - 53.1)
5.4 - 6.0
(47.8 - 53.1)
5.4 - 6.0
(47.8 - 53.1)
9.0 - 11
(79.7 - 97.4)

Advertisement

Table of Contents
loading

Table of Contents