8 Keypad: Names and Functions
Symbol
Name
LO/RE Selection Key
F
STOP Key
G
Left Arrow Key
Up Arrow Key/Down Arrow
Key
/
H
Right Arrow Key (RESET)
ENTER Key
RUN Key
I
J
USB Terminal
K
RJ-45 Connector
L
Clock Battery Cover
M
Insulation Sheet
N
Nameplate
WARNING
Sudden Movement Hazard. If you change the control source when b1-07 = 1 [LOCAL/REMOTE Run Selection =
Accept Existing RUN Command], the drive can start suddenly. Before you change the control source, remove all personnel from the
area around the drive, motor, and load. Sudden starts can cause serious injury or death.
52
Switches drive control for the Run command and frequency reference between the keypad (LOCAL) and an external source (REMOTE).
Note:
• The LOCAL/REMOTE Selection Key continuously stays enabled after the drive stops in Drive Mode. If the application must not
switch from REMOTE to LOCAL because it will have a negative effect on system performance, set o2-01 = 0 [LO/RE Key Function
Selection = Disabled] to disable
• The drive will not switch between LOCAL and REMOTE when it is receiving a Run command from an external source.
Stops drive operation.
Note:
Push
to stop the motor. This will also apply when a Run command (REMOTE Mode) is active at an external Run command
source. To disable
priority, set o2-02 = 0 [STOP Key Function Selection = Disabled].
• Moves the cursor to the left.
• Goes back to the previous screen.
• Scrolls up or down to show the next item or the previous item.
• Selects parameter numbers, and increments or decrements setting values.
• Moves the cursor to the right.
• Continues to the next screen.
• Resets the drive to clear a fault.
• Enters parameter values and settings.
• Selects menu items to move between keypad displays.
• Selects each mode, parameter, and set value.
Starts the drive in LOCAL Mode.
Starts the operation in Auto-Tuning Mode.
Note:
Before you use the keypad to operate the motor, push
For factory adjustment
Connects to the drive using an RJ-45 8-pin straight through UTP CAT5e extension cable or keypad connector.
Remove this cover to install or replace the clock battery.
Note:
• The battery included with the keypad is for operation check. It may be exhausted earlier than the expected battery life described in the
manual.
• Refer to "Maintenance & Troubleshooting Manual (TOEPYAIGA8001)" for details on replacement procedure.
To replace the battery, use a Hitachi Maxell "CR2016 Lithium Manganese Dioxide Lithium Battery" or an equivalent battery with these
properties:
• Nominal voltage: 3 V
• Operating temperature range: -20 °C to +85 °C (-4 °F to +185 °F)
An insulating sheet is attached to the keypad battery to prevent battery drain. Remove the insulation sheet before you use the keypad for the
first time.
Shows the model number of the keypad and other information
Note:
• "REV" identifies the hardware and software version of the keypad.
• "FLASH" identifies the version of the flash memory.
YASKAWA TOEPC7106171FD FP605 DRIVE INSTALLATION & PRIMARY OPERATION