No structural material on the fryer should be altered or removed to accommodate placement of the
fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.
Do not block the area around the base or under the fryers.
Do not use water jets to clean this equipment.
If the electrical power supply cord is damaged, it must be replaced by a Frymaster Factory
Authorized Servicer or a similarly qualified person in order to avoid a hazard.
Use caution when dropping large amounts of food into the hot oil. It may cause large amounts of
foaming, which can overflow and may cause burns.
Opening the drain valve will lead to the outflow of the hot contents of the fryer that can cause
injury.
This equipment is to be installed in compliance with the basic plumbing code of the Building Officials
and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the
U.S. Food and Drug Administration.
This equipment must be installed in accordance with the appropriate national and local codes of the
country and/or region in which the appliance is installed. For the United States and Canada these
are the National Fuel Gas Code, ANSI Z233.1/NFPA 54, or the Natural Gas and Propane Installation
Code, CSA B149.1. See NATIONAL CODE REQUIREMENTS in Chapter 2 of this manual for specifics.
The gas manifold of this appliance or of the battery of which it is a part must be connected to a gas
appliance pressure regulator adjusted for the manifold pressure marked on the rating plate.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa/13.84
inches W.C.).
The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than ½ psi (3.5 kPa/13.84 inches W.C.).
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must
be posted in a prominent location. This information can be obtained from the local gas company or
gas supplier.
The Commonwealth of Massachusetts requires any and all gas products to be installed by a
licensed plumber or pipe fitter.
DANGER
WARNING
WARNING
WARNING