5. PARAMETERS
Class No. Symbol
27
*ENR Encoder output pulses
www.DataSheet4U.com
28
29
30
31
32
33
MBR
34
Used to set the encoder pulses (A-phase or B-phase) output by the
servo amplifier.
Set the value 4 times greater than the A-phase or B-phase pulses.
You can use parameter No. 54 to choose the output pulse designation
or output division ratio setting.
The number of A/B-phase pulses actually output is 1/4 times greater
than the preset number of pulses.
The maximum output frequency is 1.3Mpps (after multiplication by
4). Use this parameter within this range.
For output pulse designation
Set " 0
" (initial value) in parameter No. 54.
Set the number of pulses per servo motor revolution.
Output pulse
set value [pulses/rev]
At the setting of 5600, for example, the actually output A/B-phase
pulses are as indicated below:
A B-phase output pulses
For output division ratio setting
Set " 1
" in parameter No. 54.
The number of pulses per servo motor revolution is divided by the
set value.
Resolution per servo motor revolution
Output pulse
At the setting of 8, for example, the actually output A/B-phase
pulses are as indicated below:
A B-phase output pulses
TL1
Internal torque limit 1
Set this parameter to limit servo motor torque on the assumption
that the maximum torque is 100[%].
When 0 is set, torque is not produced.
(Note)
External
input
signals
TL1
0
Internal torque limit value 1 (parameter No. 28)
1
Parameter No. 76
Parameter No. 76
Note.0 :off
1 :on
When torque is output in analog monitor output, this set value is the
maximum output voltage ( 8V). (Refer to Section 3.4.1, (5))
For manufacturer setting
Don't change this value by any means.
For manufacturer setting
Don't change this value by any means.
MO1
Analog monitor 1 offset
Used to set the offset voltage of the analog monitor 1 (MO1).
MO2
Analog monitor 2 offset
Used to set the offset voltage of the analog monitor 2 (MO2).
Electromagnetic brake sequence output
Used to set the delay time (Tb) between electronic brake interlock
(MBR) and the base drive circuit is shut-off.
GD2
Ratio of load inertia moment to servo motor inertia moment
Used to set the ratio of the load inertia moment to the servo motor
shaft inertia moment. When auto tuning mode 1 and interpolation
mode is selected, the result of auto tuning is automatically used.
(Refer to section 7.1.1)
In this case, it varies between 0 and 1000.
Name and function
5600
1400[pulse]
4
Set value
10000
1
313[pulse]
8
4
Torque limit value made valid
Parameter No. 28: Parameter No. 28
Parameter No. 28: Parameter No. 76
5 - 13
Initial
Unit
value
4000
pulse/
rev
[pulses/rev]
100
%
0
0
0
mV
0
mV
100
ms
70
0.1
times
Setting
Control
range
mode
1
P S
to
65535
0
P S
to
100
999
P S
to 999
999
P S
to 999
0
P S
to
1000
0
P S
to
3000