13. OPTIONS AND AUXILIARY EQUIPMENT
13.2.2 No-fuse breakers, fuses, magnetic contactors
Always use one no-fuse breaker and one magnetic contactor with one servo amplifier. When using a fuse
instead of the no-fuse breaker, use the one having the specifications given in this section.
Servo amplifier
MR-E-10A
MR-E-20A
MR-E-40A
MR-E-70A
MR-E-100A
MR-E-200A
www.DataSheet4U.com
13.2.3 Power factor improving reactors
The input power factor is improved to be about 90%. For use with a 1-phase power supply, it may be
slightly lower than 90%.
RX S Y T Z
C
Servo amplifier
MR-E-10A/20A
MR-E-40A
MR-E-70A
MR-E-100A
MR-E-200A
No-fuse breaker
Class
30A frame 5A
K5
30A frame 5A
K5
30A frame 10A
K5
30A frame 15A
K5
30A frame 15A
K5
30A frame 20A
K5
W
D1 5
Installation screw
W1
Model
W
FR-BAL-0.4K
135 (5.31) 120 (4.72) 115 (4.53)
FR-BAL-0.75K
135 (5.31) 120 (4.72) 115 (4.53)
FR-BAL-1.5K
160 (6.30) 145 (5.71) 140 (5.51)
FR-BAL-2.2K
160 (6.30) 145 (5.71) 140 (5.51)
FR-BAL-3.7K
220 (8.66) 200 (7.87) 192 (7.56)
Fuse
Magnetic contactor
Current [A]
Voltage [V]
10
10
15
AC250
15
15
15
[Unit : mm]
NFB
3-phase
200 to 230VAC
NFB
1-phase
230VAC
Dimensions [mm (in) ]
W1
H
D
59 (2.32)
45 (1.77)
69 (2.72)
57 (2.24)
71 (2.79)
55 (2.17)
91 (3.58)
75 (2.95)
90 (3.54)
70 (2.76)
13 - 23
S-N10
S-N18
FR-BAL
MC
R
X
S
Y
T
Z
FR-BAL
MC
R
X
S
Y
T
Z
Mounting
Terminal
screw size
screw size
D1
C
7.5 (0.29)
M4
M3.5
7.5 (0.29)
M4
M3.5
7.5 (0.29)
M4
M3.5
7.5 (0.29)
M4
M3.5
10 (0.39)
M5
M4
Servo amplifier
L
1
L
2
L
3
Servo amplifier
L
1
L
2
L
3
Weight
[kg (lb)]
2.0 (4.4)
2.8 (6.17)
3.7 (8.16)
5.6 (12.35)
8.5 (18.74)