15. MR-E-
Class No. Symbol
47
www.DataSheet4U.com
*LSPN LSP/LSN input terminal selection
48
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Input signal selection 6 (CN1-7)
*DI6
Allows any input signal to be assigned to CN1-pin 7.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).
0
0
Speed
control mode Input signals of
Torque
control mode
This parameter is unavailable when parameter No. 42 is set to
assign the control change signal (LOP) to CN1-pin 7.
If forward rotation stroke end (LSP) is assigned to pin 7 of Cn1 with
parameter No. 48, this parameter cannot be used.
Select the pins where the forward rotation stroke end (LSP) and
reverse rotation stroke end (LSN) will be assigned. If the signals
have already been assigned using parameter No. 42 to 47, this
parameter setting has preference.
However, if forward rotation stroke end (LSP) is assigned to pin 6 of
CN1 (default setting), the setting of parameter No. 46 takes priority.
Similarly, if reverse rotation stroke end (LSN) is assigned to pin 7 of
CN1 (default setting), the setting of parameter No .47 takes priority.
0
0
Select the pin where the forward rotation stroke
end (LSP) will be assigned.
Set value Connector pin No.
Select the pin where the reverse rotation stroke
end (LSN) will be assigned. The settings are the
same as those of the first digit.
Name and function
CN1-pin 7
selected.
0
CN1-5
1
2
CN1-4
3
CN1-6
4
CN1-7
5
CN1-3
15 - 45
Initial
Setting
Control
Unit
value
range
mode
0000
S T
Refer to
Name
and
function
column.
0403
S T
Refer to
Name
and
function
column.