5. PARAMETERS
Class No. Symbol
50
51
*OP6
www.DataSheet4U.com
52
53
*OP8
54
*OP9
Name and function
For manufacturer setting
Don't change this value by any means.
Function selection 6
Used to select the operation to be performed when the reset (RES)
switches on.
0
0 0
Operation to be performed when the
reset (RES) switches on
0: Base circuit not switched off
1: Base circuit switched off
For manufacturer setting
Don't change this value by any means.
Function selection 8
Used to select the protocol of serial communication.
0
0
Protocol checksum selection
0: Yes (checksum added)
1: No (checksum not added)
Protocol checksum selection
0: With station numbers
1: No station numbers
Function selection 9
Use to select the command pulse rotation direction, encoder output
pulse direction and encoder pulse output setting.
0
Servo motor rotation direction changing
Changes the servo motor rotation
direction for the input pulse train.
Set value
0
1
Encoder pulse output phase changing
Changes the phases of A/B-phase encoder pulses output .
Set value
CCW
A phase
0
B phase
A phase
1
B phase
Encoder output pulse setting selection (refer to parameter No. 27)
0: Output pulse setting
1: Division ratio setting
Servo motor rotation direction
At forward rotation
At reverse rotation
pulse input
pulse input
CCW
CW
CW
CCW
Servo motor rotation direction
CW
A phase
B phase
A phase
B phase
5 - 20
Initial
Setting
Control
Unit
value
range
mode
0000
0000
P S
Refer to
Name
and
function
column.
0000
0000
P S
Refer to
Name
and
function
column.
0000
P S
Refer to
Name
and
function
column.