15. MR-E-
15.3 Startup
WARNING
CAUTION
Perform pre-operation checks while referring to Section 4.1. Connect the servo motor with a machine after
www.DataSheet4U.com
confirming that the servo motor operates properly alone.
Use parameter No. 0 to choose the control mode used. After setting, this parameter is made valid by
switching power off, then on.
15.3.1 Speed control mode
(1) Power on
1) Switch off the servo-on (SON).
2) When power is switched on, the display shows "r (servo motor speed)", and in two second later,
shows data.
(2) Test operation
Using jog operation in the test operation mode, make sure that the servo motor operates. (Refer to
Section 6.8.2.)
(3) Parameter setting
Set the parameters according to the structure and specifications of the machine. Refer to Chapter 5 for
the parameter definitions and to Sections 6.5 for the setting method.
Parameter No.
0
1
2
8
9
10
11
12
13
Turn the power off to validate changes in parameters No. 0 and 1. Then switch power on again to
make the set parameter values valid.
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Do not operate the switches with wet hands. You may get an electric shock.
Before starting operation, check the parameters. Some machines may perform
unexpected operation.
During power-on for some after power-off, do not touch or close a parts (cable etc.)
to the servo amplifier heat sink, regenerative brake resistor, the servo motor, etc.
Their temperatures may be high and you may get burnt or a parts may damaged.
Name
Control mode, regenerative brake
option selection
Function selection 1
Auto tuning
Internal speed command 1
Internal speed command 2
Internal speed command 3
Acceleration time constant
Deceleration time constant
S-pattern acceleration/deceleration
time constant
Setting
0 2
Speed control mode
Regenerative brake option is not used.
1 2
Input filter 3.555ms (initial value)
Electromagnetic brake interlock (MBR) is used.
1 5
Middle response (initial value) is selected.
Auto tuning mode 1 is selected.
1000
Set 1000r/min.
1500
Set 1500r/min.
2000
Set 2000r/min.
1000
Set 1000ms.
500
Set 500ms.
0
Not used
15 - 25
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents