7 Servicing/Maintenance

7.6 Reassembling the pump set

7.6.1 General information/Safety regulations

DANGER
Wrong screws/bolts
Explosion hazard!
▷ Always use the original screws/bolts for assembling an explosion-proof pump
set.
▷ Never use screws/bolts of different dimensions or of a lower property class.
WARNING
Screwed/bolted connections working loose
Risk of injury!
▷ If persons come into contact with the fluid handled during pump operation
(e.g. in sports facilities and leisure parks), apply a thread-locking agent (Loctite,
type 243) to all screwed/bolted connections that are in contact with the fluid
handled. Do not apply the thread-locking agent (Loctite, type 243) to the screw
plugs.
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷ Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
WARNING
Components with sharp edges
Risk of cutting or shearing injuries!
▷ Always use appropriate caution for installation and dismantling work.
▷ Wear work gloves.
WARNING
Insufficient stability
Risk of crushing hands and feet!
▷ During assembly/dismantling, secure the pump (set)/pump parts to prevent
tilting or tipping over.
CAUTION
Improper reassembly
Damage to the pump!
▷ Reassemble the pump (set) in accordance with the general rules of sound
engineering practice.
▷ Use original spare parts only.