Fitting The Motor Housing Cover - KSB Amacan P 500-270 Installation & Operating Manual

Submersible pump in discharge tube
Hide thumbs Also See for Amacan P 500-270:
Table of Contents

Advertisement

Installing the sensor cable
7 Servicing/Maintenance
4. Insert cable gland 834.01 with the power cable and O-ring 412.07 into the
opening provided.
5. Fasten cable gland 834.01 with hexagon socket head cap screws 914.04. Secure
the screwed connection with Loctite 243.
6. Fit cable terminals to the core ends of the power cable.
ü The motor housing cover has been removed, placed down and protected against
rolling off.
1. Adjust the lengths of the cable cores to those of the original cable gland.
2. Attach core identifications matching the original cable gland.
3. Slide O-ring 412.08 over the short core ends of the sensor cable and into the
groove of the centring seat.
4. Insert cable gland 834.02 with the sensor cable and O-ring 412.08 into the
opening provided.
5. Fasten cable gland 834.02 with hexagon socket head cap screws 914.05 and
secure the screwed connection with Loctite 243.

7.6.3 Fitting the motor housing cover

DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock and explosion!
▷ Always have the electrical connections installed by an electrically qualified
person.
▷ Observe regulations IEC 60364 and, for explosion-proof versions, EN 60079 .
82-11
68-3.02
903.04
411.04
550.23
932.23
835
901.20
932.20
Fig. 39: Fitting the motor housing cover
a
Anti-rotation device of the
bearing housing
Amacan P
571
571
901.26
812
b
a
L
914.03
243
350.02
80-1
b
Recess for anti-rotation device in
the motor housing cover
67 of 112

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amacan p 600-350

Table of Contents