6 Commissioning/Start-up/Shutdown

6 Commissioning/Start-up/Shutdown

6.1 Commissioning/Start-up

6.1.1 Prerequisites for commissioning/start-up

DANGER
Operating the pump set without protective equipment
Electric shock!
Risk of injury!
Danger of death from drowning!
▷ Never start up the pump set without special protective equipment when there
are persons in the tank.
▷ If persons come into contact with the fluid handled during pump operation
(e.g. in sports facilities and leisure parks), the plant designer/operator must
comply with the legal requirements.
▷ Provide special electrical and mechanical protective equipment compliant with
the legal regulations.
WARNING
Operating the pump set without mechanical protective equipment
Risk of injury from solid matter in the fluid handled!
▷ If persons come into contact with the fluid handled during pump operation
(e.g. in sports facilities and leisure parks), install mechanical protective
equipment (e.g. a screen) on the discharge side of the pump set.
WARNING
People falling into the unsecured discharge tube
Risk of personal injury!
▷ Take suitable precautions during the entire installation/removal process to
protect people from falling into the open discharge tube.
▷ Fence off the work area appropriately.
Before commissioning/starting up the pump set, make sure that the following
conditions are met:
▪ The lubricant has been checked.
▪ The direction of rotation has been checked.
▪ The pump set has been properly connected to the power supply and is equipped
with all protection devices.
▪ The pump set has been installed in the discharge tube as described in this
manual.
▪ The minimum fluid level has been reached.
▪ After prolonged shutdown of the pump (set), the activities required for returning
the equipment to service have been carried out. (ð Section 6.4, Page 47)
▪ Safety-relevant protective equipment must be installed and fully functional.