Installation With A Support Rope And Support Spacer - KSB Amacan P 500-270 Installation & Operating Manual

Submersible pump in discharge tube
Hide thumbs Also See for Amacan P 500-270:
Table of Contents

Advertisement

32 of 112
5 Installation at Site

5.3.4 Installation with a support rope and support spacer

Always refer to and comply with the general arrangement drawing/outline drawing
when installing the pump set.
1. Prior to installing the pump set, visually inspect the support rope.
2. Do not exceed the permissible load-carrying capacity.
X
59-24
X
59-17.01
Fig. 18: X = indication of load-carrying capacity
59-24
Support rope
59-17.01
Shackle
CAUTION
Incorrect installation
Damage to the pump set!
▷ Verify that the pump set is correctly seated in the discharge tube.
WARNING
Pump set drops during the installation or removal process
Personal injury and damage to property!
▷ Never use the turnbuckle , shackle or discharge tube cover to lift the pump set.
▷ Always use lifting lug 59-47.
NOTE
Prior to fitting the turnbuckle, check that the corresponding split pin has not been
cracked or chipped. If damaged, always use a new split pin.
ü Suitably sized lifting equipment is available.
ü The support has been supplied pre-assembled and is available for use.
ü The support rope has been visually inspected.
ü The split pin of the turnbuckle has been checked for any damage.
412.05
112
Fig. 19: Inserting the O-ring
1. If not already fitted, insert the supplied O-ring 412.05 into pump bowl 112.
Amacan P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amacan p 600-350

Table of Contents