5 Installation at Site
2
3
1
Fig. 14: Lifting and positioning the pump set
2. Secure the lifting chain or lifting rope (1) to the trolley (4) of the lifting
equipment (2).
3. Attach the support rope (5) to the bail by its shackle. (ð Section 9.2, Page 82)
For a galvanised shackle, secure the pin at the shackle with Loctite 243.
For a stainless steel shackle, undo and tighten the pin twice and secure it with
Loctite 243.
4. Check that the support rope is arranged correctly.
ð The free lifting lug (6) has to point away from the pump set
5. Partially unwind the support rope and electric cables.
6. Lower the pump set into the discharge tube until the bail is in an accessible
position, protruding from the discharge tube.
7. Securely cover the discharge tube except for a gap which allows work to
continue.
8. Attach the first lifting lug of the support rope (5) to the lifting rope (1) to
securely position the pump set above the discharge tube.
9. Unclip the hook of the lifting equipment from the lifting lug of the support
rope and run the lifting equipment to a higher level.
9
7
8
Fig. 15: Securing the control cable and power cable
10. Secure the control cable (7) and power cables (8) to the crane hook (3) of the
lifting equipment with a manila rope (9).
11. Trim spacer (a) to fit between the two ferrules.
Amacan P
4
5
6