5 Installation at Site
d
c
b
e
a
f
Fig. 16: Cross-section of the cable guide
12. Insert the support rope (f) and the control cable (c) into the spacer (a) and make
sure that they are in their respective ducts.
13. Tighten the electric cables with the manila rope running over the crane hook.
14. Insert the power cables (b) into the hollows of the spacer (a) and, starting from
the bottom, firmly clamp the power cables with cable clamps (d) covered by a
plastic sheath (e).
15. In the area of the lifting lug between the rope sections, lay all electric cables in
loops and fasten them to the rope section above.
16. Progressively lower the pump set into the discharge tube while securing the
cable bundle with evenly spaced sheathed cable clamps.
17. Fit a heat shrink tube on any protruding sharp-edged rope ends (e.g. at the
ferrule) to prevent any damage to the power cable and control cable.
Fig. 17: Lowering the pump set
18. Finally, attach the support rope with shackle and turnbuckle to a suspension
loop (provided in the discharge tube or structure). Secure the turnbuckle with a
split pin. After inserting the split pin, bend over its two legs.
19. Tighten the turnbuckle until the cable bundle is tight without lifting the pump
off its seat.
20. Unclip the hook of the lifting equipment from the lifting lug, free the electric
cables from the manila rope and route them to the control cabinet.
21. Make sure that the top loose lifting lug is attached to the cable bundle to
prevent noise and wear caused by chafing.
22. Remove the safety cover from the discharge tube and mount the discharge tube
cover. Seal the cable entries if any!