Installation Type Dg - KSB Amacan P 500-270 Installation & Operating Manual

Submersible pump in discharge tube
Hide thumbs Also See for Amacan P 500-270:
Table of Contents

Advertisement

1
2
4
0 - 90°
v
= 1 m/s
max.
①: Vent line
②: Minimum water level (values see diagram on the next page)
③: Flow-straightening vane (ð Section 9.6.7, Page 105)
④: Approach flow
⑤: Not pressure-proof
⑥: Connect the discharge pipe to the pump without transmitting any stresses or
strains.
Table 44: Dimensions [mm]
Size
DN
DN
2 min.
500-270
300
600-350
350
Table 45: Dimensions [mm]
25)
Size
e
1
500-270
259
375
600-350
375
625
24
All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
25
Observe this dimension.
26
Value for maximum motor length
9 Related Documents

9.6.6 Installation type DG

X
6
a
5
A
A
D
Y
B
d
10
e
2
B - B
e
l
1
3
b
2
D
a
2 max.
500
508
530
650
600
610
580
760
e
h
l
2
7
min.
295
750
540
1250
Amacan P
B
a
a
b
b
1
2
1
400
750
150
510
1250
250
m
n
p
1
720
950
650
830
1060
760
a
1
a
200
200
2
24)
Foundation recesses
300
200
Section A - A:
m
Detailed view X:
Support plate of the discharge
tube
Drawing: without pump
Y
s
1
d
7
d
8
Detailed view Y:
seating ring
b
d
d
2
7
8
300
400
505
500
500
610
25)
26)
p
t
t
2
3
4 min.
750
200
1700
860
320
2000
103 of 112
d
10
540
640
t
9
280
470

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amacan p 600-350

Table of Contents