412.05
112
Fig. 10: Inserting the O-ring
28 of 112
5 Installation at Site
1
2
3
Fig. 9: Installation position of the pump set
1
Bail
3
Flow-straightening vane

5.3.2 Installation without support rope

CAUTION
Incorrect installation
Damage to the pump set!
▷ Verify that the pump set is correctly seated in the discharge tube.
Refer to and comply with the general arrangement drawing/outline drawing when
installing the pump set.
1. If not already fitted, insert the supplied O-ring 412.05 into pump bowl 112.
2. Attach the crane hook to the bail of the pump set.
3. Centre the pump set above the discharge tube. Slowly lower the pump set into
the discharge tube until it is seated in the recommended position.
(ð Section 5.3.1, Page 27)
4. Pull the electric cables up by hand. Fasten them to the sump construction with a
cable support sleeve if required. Do not lift the pump set out of its seat.
X
X
Fig. 11: Fastening the cable support sleeve
Amacan P
2
Anti-swirl baffles