7 Servicing/Maintenance
7.4.1.3 Lubricant quantity
Table 15: Lubricant quantity
Size
500 - 270
600 - 350
7.4.1.4 Changing the lubricant
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷ When draining the lubricant take appropriate measures to protect persons and
the environment.
▷ Wear safety clothing and a protective mask if required.
▷ Collect and dispose of any lubricants.
▷ Observe all legal regulations on the disposal of fluids posing a health hazard.
WARNING
Excess pressure inside the pump set
Risk of injury when opening the pump set!
▷ Take care when opening the inner chambers. Equalise the pressure.
WARNING
Improper handling when placing the pump set in a vertical/horizontal position
Personal injury and damage to property!
▷ Select suitable lifting equipment for the size of the pump.
▷ Use appropriate means to secure the pump set against tilting, tipping over or
rolling off.
▷ Maintain a safe distance during lifting operations (load may swing when being
lifted).
▷ Use additional supports for the transport holder to secure it against tilting.
7.4.1.4.1 Draining the lubricant
903.01
411.01
903.03
Fig. 30: Draining the lubricant
1. Place the pump set down in a horizontal position. Secure it against rolling off.
2. Remove screw plug 903.03.
3. Remove screw plug 903.01 and joint ring 411.01.
4. Screw in a sufficiently long tube (2) with G 1/2 thread.
Amacan P
2
Lubricant quantity
[l]
0.46
0.65
57 of 112