KSB Amacan P 500-270 Installation & Operating Manual page 64

Submersible pump in discharge tube
Hide thumbs Also See for Amacan P 500-270:
Table of Contents

Advertisement

Removing the power cable
Removing the sensor cable
64 of 112
7 Servicing/Maintenance
5. Lift the motor housing cover up further until the power and control cables can
be disconnected.
6. Disconnect the cores of the control cable from the corresponding connector.
7. Disconnect the cores of the power cable from terminal board 835. Disconnect
the earth conductor and the shield of shielded cables from bearing housing 350.
8. Place motor housing cover 812 down and secure it against rolling off.
7.5.6.2 Removing the cable gland and connection cable
571
914.05
A
834.02
914.04
Fig. 37: Removing the cables and cable gland
ü The motor housing cover has been removed, placed down and protected against
rolling off.
1. Remove cover plate 82-11 or 68-3.02 from bail 571. Take out the cable gland
834.01/02 needing to be replaced.
2. Disconnect the earth connector on the inside of motor housing cover 812. If a
shielded cable is used, disconnect the shield as well.
3. Undo screws 914.04 at cable gland 834.01.
4. Pull cable gland 834.01 out of the centring seat in motor housing cover 812.
ü The motor housing cover has been removed, placed down and protected against
rolling off.
1. Disconnect the cores of the sensor cable from plug 81-2.
2. Undo screws 914.05 at cable gland 834.02.
3. Pull cable gland 834.02 out of the centring seat in motor housing cover 812.
NOTE
Keeping a record of the core identification and lengths is recommended. This will
facilitate installing the replacement cable gland.
Amacan P
68-3.02
(82-11)
81-18.03
834.01
901.20
932.20
A
812
81-29.03
A - A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amacan p 600-350

Table of Contents