1.2 System Features
The following views of the system display the main features. Refer to
specifications.
Front View
8
0
1
Item
Description
0-5
4x E1.S and 2x 2.5" 7mm Hot-swap NVMe/SATA3 drive bays
6
USB 2.0 ports
7
Control panel (see next page for details)
8
Master tray locking levers
Note: Orange denotes the logical drive number.
Drive Carrier Indicators (EDSFF and 2.5" drives only)
Each drive carrier has two LED indicators: an activity indicator and a status indicator. For
RAID configurations using a controller, the meaning of the status indicator is described in
the table below. For OS RAID or non-RAID configurations, some LED indications are not
supported, such as hot spare.
Color
Activity
Blue
LED
Blue
Status
Red
LED
Red
Red
Red
Red
Green
Amber
2
3
4
Figure 1-1. Front View
Logical Storage Drive Numbers
Drive Carrier LED Indicators
Blinking Pattern
Behavior for Device
Solid On
SATA/SAS/NVMe drive installed
Blinking
I/O activity
Solid On
Failure of drive with RSTe support
Blinking at 1 Hz
Rebuilding drive with RSTe support
Blinking with two blinks
Hot spare for drive with RSTe support
and one stop at 1 Hz
(not supported in VMD mode)
On for five seconds,
Power on for drive with RSTe support
then off
Blinking at 4 Hz
Identify drive with RSTe support
Solid On
Safe to remove NVMe device
(not supported in VMD mode)
Blinking at 1 Hz
Attention state-do not remove NVMe device
(not supported in VMD mode)