Hot-Swap for NVMe Drives

Supermicro servers support NVMe surprise hot-swap. For even better data security, NVMe
orderly hot-swap is recommended. NVMe drives can be ejected and replaced remotely using
BMC.
Note: If you are using VROC, see the VROC appendix in this manual instead.
Ejecting a Drive
1. BMC > Server Health > NVMe SSD
2. Select Device, Group and Slot, and click Eject. After ejecting, the drive Status LED
indicator turns green.
3. Remove the drive.
Note that Device and Group are categorized by the CPLD design architecture. The
SSG-610P-ACR12N4H/L server has one Device and one Group, except the 2029U-TN24
server which has one Device and two Groups.
Slot is the slot number on which the NVMe drives are mounted.
Replacing the Drive
1. Insert the replacement drive.
2. BMC > System > Storage Monitor > Physical View
3. Select Device, Group and slot and click Insert. The drive Status LED indicator flashes
red, then turns off. The Activity LED turns blue.