12 Routine Maintenance

Electro Freeze recommends the following
schedule to help maintain your soft serve
freezer in like-new operating condition.
Take the time to learn and perform these
routine procedures and receive in return
many years of valuable service from your
freezer. Protect your investment!
sanitize, air-dry, reassemble and sanitize
all parts that come into contact with the
mix or product.
tubes and drain tubes with the appropriate
brushes.
O-rings and hoses. Replace any seal,
O-ring and hose that is worn, torn, or
loose fitting.
freezer to remove any splattered mix.
the product.
38
DAILY
1. Disassemble, wash, rinse,
CAUTION
To prevent bacteria growth,
remove all O-rings when
cleaning. Failure to do so
could create a health hazard.
2. Clean the cylinders, cylinder inlet
3. When cleaning, inspect all seals,
4. Wipe all exterior surfaces of the
5. Check overrun and temperature of
AS NEEDED
CAUTION
To avoid electrical shock or
contact with moving parts,
make sure all switches are
in the "OFF" position and
that the main power supply
is disconnected. Some
freezers have more than one
disconnect switch.
1. Clean the mix transfer systems:
Important:
If the transfer hose is assembled
improperly or replacement has been
neglected, it may be necessary to
clean mix from the MTS due to hose
failure.
If this happens frequently the MTS
should be removed for complete
cleaning.
CAUTION
Make sure the freezer
is depressurized before
proceeding.
CAUTION
To avoid electrical shock or
contact with moving parts,
make sure all switches are
in the "OFF" position and
that the main power supply
is disconnected. Some
freezers have more than one
disconnect switch.