Disassembly Instructions - ELECTRO FREEZE GENESIS Series Operator's Manual

Soft serve freezer
Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Model GEN-5400

7.2 Disassembly Instructions

Figure 7-2 Head Assembly
22
CAUTION
To avoid electrical shock or
contact with moving parts,
make sure all switches are
in the "OFF" position and
that the main power supply
is disconnected. Some
freezers have more than one
disconnect switch.
CAUTION
Make sure freezer is
depressurized before
proceeding.
CAUTION
To prevent bacteria growth,
remove ALL O-rings when
disassembling for clean-
ing. Failure to do so could
create a health hazard.
Follow these directions for each cylinder:
1. If there is product in the freezer,
refer to Section 10, Closing Procedures,
10.2 Draining Product.
2. Remove the plunger rods (7,
figure 7-2) by lifting up and swinging the
bottom out and down. Remove hand
knobs (11) and pull the dispensing head
(1) straight out.
3. Remove the bushings and beater
shafts from the cylinders.
4. Remove scraper blades and shaft
seal from the beater shaft.
5. Remove the drip tray (see
Replacement Parts Manual, Panel
Assembly) and drip tray insert from the
front of the freezer.
6. Remove the air bleed plug (6) and
remove the two O-rings (5).
– continued
184297

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gen-5400

Table of Contents