Routine Maintenance - ELECTRO FREEZE SOFT SERVE TWIST SL500 Operator's Manual

Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Model SL500
11

ROUTINE MAINTENANCE

To protect the unit during seasonal shutdown, it is important to store the freezer
properly. Use the following procedures:
a warm, mild detergent solution. Rinse in clear water and air dry all parts thoroughly.
Clean drain tube and all exterior panels.
a safe dry place.
elements that could contaminate them while in storage. Place the freezer in a dry
location.
rized service technician.
air to blow out all remaining water in the condenser.
The water valve must be opened in order to blow out the condenser. Failure to
purge the freezer of water can result in severe damage to the refrigeration
system. Call your Electro Freeze Distributor for service.
o-rings and seals with new parts. Rubber parts can lose their elasticity and ability to
seal when stored.
USE ONLY ORIGINAL OR AUTHORIZED REPLACEMENT PARTS WITH THIS FREEZER.
If you have any questions on items that are not included in this schedule or problems that require
service assistance, please call your local distributor or H.C. Duke & Son, LLC, Electro Freeze,
32
WINTER STORAGE
1. Disconnect all power to the freezer.
2. Disassemble and wash all parts that come into contact with the mix using
3. Store the loose parts, such as the head assembly and beater assembly, in
4. Do not lay heavy objects on the plastic or rubber parts.
5. Cover the freezer and all loose parts to protect them from dust or other
6. If you have an air cooled freezer, have condenser fins cleaned by an autho-
7. On water-cooled freezers, disconnect the water supply. Use compressed
8. When freezer is restarted after seasonal shutdown, remember to replace all
Service Department for factory service assistance.
Phone: (309) 755-4553 or (800) 755-4545
E-mail: service@electrofreeze.com
Important:
FAX: (309) 755-9858.
184599