7. Press the Left/Right key to select Export and press [Enter].
8. Press the Left/Right key to select Yes and press [Enter].
9. Set the name of the List file to be exported, and press [Enter].
Run the List Program
You can select a List file to execute according to your needs, so that the power
supply outputs the corresponding waveform sequence. Take the List file in
Internal as an example. The steps are as follows:
1. Press the composite keys [Shift]+[I-set] (Function) on the front panel to en-
2. Select 1. LIST: Off and press [Enter].
3. Press the Left/Right key to select Open and press [Enter].
4. Press the Left/Right key to select Internal and press [Enter].
5. Set the name of the List file to be recalled (that is, the file name set in Edit),
6. Press the Left/Right key to select Run and press [Enter].
7. Turn on the [On/Off].
8. Based on the selected trigger method, perform the trigger operation.
The interface returns to the main interface of the LIST function, which is dis-
played as follows:
FUNCTION
LIST
Run Edit Open Export
Indicates that the selected List file in Open is exported to the USB flash
drive.
ter the function menu.
and press [Enter].
The interface returns to the main interface of the LIST function, which is dis-
played as follows:
FUNCTION
LIST
Run Edit Open Export
At this point, the interface returns to the main interface of the system and
LIST RUN is displayed in the lower right corner.
Take the manual trigger as an example. Press [Shift]+[On/Off](Trigger) on
the front panel to run the selected List file. For details about the List trigger
method, see
5.8 Select Trigger Source (Trig
Copyright © Itech Electronic Co., Ltd.
Power Supply Function
Source).
60