Parameter
Rise Time( full load
)
Fall Time( no load )
Fall Time( full load )
Transient Response
Time
(change from 20%
to 90% of rated
current)
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Other parameters:
*2
AC Input
Max. apparent
power
Max. input current
Max. efficiency
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower
protection
current program
current monitor
voltage program
voltage monitor
Grid voltage range
Frequency
Copyright © Itech Electronic Co., Ltd.
IT-M3906D-80-120
≤100ms
≤0.01% + 0.01%FS
≤0.03% + 0.03%FS
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
≤2V
External programming voltage 0V to 10V corre-
sponds to current 0A to 120A
Current 0A to 120A corresponds to external moni-
toring voltage 0V to 10V
External programming voltage 0 to 80V Corre-
sponding voltage 0 to 10V
Voltage 0 to 80V corresponds to external monitor-
ing voltage 0 to 10V
3phase 200V~480V
Single phase 100V~240V
6.5kVA
12.5Aac
92%
Technical Specification
≤30ms
≤1s
≤1ms
125A
82V
6120W
50/60Hz
136