Parameter
Load Regulation
Output protection
Remote Sense Com-
pensation Voltage
External analog
(optional)
Other parameters:
AC Input
*1
Max. apparent
power
Max. input current
Max. efficiency
Power Factor
DC component
Current harmonics
Standard Interface
Command Re-
sponse Time
Parallel Number
Working
Temperature
Storage
Temperature
Voltage
Current
OCP
OVP
Overpower
protection
current program
current monitor
voltage program
voltage monitor
Grid voltage range
Frequency
Optional: GPIB/Analog&RS232
Copyright © Itech Electronic Co., Ltd.
IT-M3912D-500-72
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
≤5V
External programming voltage 0V to 10V corre-
sponds to current 0A to 72A
Current 0A to 72A corresponds to external moni-
toring voltage 0V to 10V
External programming voltage 0 to 500V Corre-
sponding voltage 0 to 10V
Voltage 0 to 500V corresponds to external moni-
toring voltage 0 to 10V
3phase 200V~480V
13kVA
25Aac
94.5%
0.99
≤0.2A
≤3%
Standard: USB/LAN/CAN/IO
0.1ms
≤16
0~40℃
-10℃~70℃
Technical Specification
74A
505V
12240W
50/60Hz
159