Parameter
Other parameters:
AC Input
*2
Max. apparent
power
Max. input current
Max. efficiency
Power Factor
DC component
Current harmonics
Standard Interface
Command Re-
sponse Time
Parallel Number
Working
Temperature
Storage
Temperature
IP
Isolation DC to GND
Isolation AC to GND
Cooling
Dimension
(D*W*H)
Weight( net)
voltage monitor
Grid voltage range
Frequency
*1: The ripple is got under three-phase AC input.
*2: At low voltage input, the set power will decrease. For more information,
please contact ITECH.
Copyright © Itech Electronic Co., Ltd.
IT-M3906D-1500-12
Voltage 0 to 500V corresponds to external moni-
toring voltage 0 to 10V
3phase 200V~480V
Single phase 100V~240V
6.5kVA
12.5Aac
94.5%
0.99
≤0.2A
≤3%
Standard: USB/LAN/CAN/IO
Optional: GPIB/Analog&RS232
0.1ms
≤16
0~40℃
-10℃~70℃
IP20
1800Vdc
3500Vdc
Air
744.22mm*459mm*56.81mm
15kg
Technical Specification
50/60Hz
172